300 - Ex de Bulkhead Fitting

300 - Ex de Bulkhead Fitting
Nhà Sản Xuất : Pepperl+Fuchs
Hazardous Area Specification
|
Area Classification |
1, 21, 2, 22 |
Type of Protection |
Ex de IIC T* Gb
Ex tb IIIC T**°C Db
or
Ex d IIC T* Gb
Ex tb IIIC T**°C Db |
Temperature Info |
Amb. Temp °C |
Gas Temp
Class (T*°C) |
Dust Temp
Class (T**°C) |
Lamp
Type |
Min |
Max |
-20 |
+49 |
T6 |
85 |
CFL |
-20 |
+54 |
T5 |
100 |
CFL |
-20 |
+41 |
T4 |
135 |
GLS |
-20 |
+60 |
T3 |
200 |
GLS |
See datasheet for unit orientations |
|
Ingress Protection |
IP67 to EN60529:1992 |
Marking to 94/9/EC |
II 2 GD |
Certificate No(s) |
SIRA00ATEX1107X - Issue: 13 |
|
Enclosure Specification
|
Material |
All cast metal parts - light metal alloy
Overtube - borosilicate glass
Reflector - 1.2mm galvanized mild steel |
Finish |
Cast metal parts - Epoxy powder coat RAL7032
Reflector - epoxy powder coat - white |
Cover Fixing |
M6 allen head stainless steel screws |
Gasket |
Nitrile O ring |
Earthing |
Internal |
Mounting |
Two stainless steel mounting brackets supplied as standard |
Entry Specification
|
2 x Ex d threaded entries fitted with Ex d stopping plugs |
Electrical Specification
|
Control Gear |
High frequency electronic ballast complying with all European standards relating to safety, operation and EMC (Immunity) |
Operating Voltage |
220 - 254 Volts 50/60Hz |
Operating Current |
Compact flourescent 0.08 Amps. GLS 0.25 Amps |
Power Factor |
0.98 |
Terminals |
2.5mm� connection block. Suitable for through wiring |
Lamps |
13 Watt compact flourescent or 60 Watt GLS |
Ordering Information
|
Product Code |
Lamp |
Protection Concept |
|
300/CFL |
1 x 13 Watt compact fluorescent |
de |
|
300/GLS |
1 x 60 Watt GLS |
de |
|
350/CFL |
1 x 13 Watt compact fluorescent |
d |
|
350/GLS |
1 x 60 Watt GLS |
|